Uploads by Jlungo
From Ministry of Water DCOM Manual
This special page shows all uploaded files.
Date | Name | Thumbnail | Size | Description | Versions |
---|---|---|---|---|---|
13:07, 12 February 2020 | Screen Shot 2020-02-12 at 13.05.10.png (file) | 102 KB | 1 | ||
13:17, 12 February 2020 | Single-tap.png (file) | 104 KB | 1 | ||
13:18, 12 February 2020 | Double-tap.png (file) | 112 KB | 1 | ||
11:10, 12 February 2020 | HouseConnectionModel.png (file) | 114 KB | 1 | ||
11:50, 12 February 2020 | Connmodel.png (file) | 114 KB | cnn model | 1 | |
12:23, 12 February 2020 | Model1.png (file) | 114 KB | House Water Connection Model | 1 | |
19:10, 6 March 2020 | Water Supply Project.jpg (file) | 122 KB | Water Supply Projects | 1 | |
12:31, 12 February 2020 | Sandfilter.png (file) | 125 KB | 1 | ||
12:44, 12 February 2020 | 45m3RiserDetail v1.png (file) | 144 KB | 1 | ||
13:29, 12 February 2020 | Screen Shot 2020-02-12 at 13.27.21.png (file) | 146 KB | 1 | ||
12:43, 12 February 2020 | 45m3RiserDetail v2.png (file) | 162 KB | 1 | ||
12:34, 12 February 2020 | Roughingfilter.png (file) | 172 KB | 1 | ||
13:09, 7 March 2020 | MARK-SK-150-AutoCAD.dwg (file) | 218 KB | Spring intake structure (spring box) Drawing in AutoCAD Format | 1 | |
13:26, 12 February 2020 | Screen Shot 2020-02-12 at 13.24.48.png (file) | 229 KB | 1 | ||
11:16, 30 March 2020 | 22109.pdf (file) | 230 KB | Typical sand trap intake | 1 | |
15:43, 30 March 2020 | Break Pressure Tank.dwg (file) | 234 KB | Break pressure tank combined with Domestic point and washing slab | 1 | |
14:49, 30 March 2020 | Box kiosk design.pdf (file) | 251 KB | Substitute to domestic point type I (Box kiosk design type I) | 1 | |
18:15, 11 March 2020 | TY-ST-49.pdf (file) | 263 KB | Type pump house for centrifugal pump | 1 | |
13:03, 7 March 2020 | MARK-SK-150.pdf (file) | 274 KB | Spring intake structure (spring box) | 1 | |
12:15, 7 March 2020 | TS-YT-40-2020-03-07.pdf (file) | 278 KB | Intake of clear stream-to be found on rock and soft ground | 1 | |
16:41, 11 March 2020 | DCOM Volume I 2020-03-11.png (file) | 284 KB | DCOM Volume I Cover Page | 1 | |
14:38, 30 March 2020 | Domestic Point.pdf (file) | 305 KB | Domestic point type 1A & 1B | 1 | |
12:40, 12 February 2020 | 45m3RiserDetail1.png (file) | 306 KB | 1 | ||
10:30, 31 March 2020 | Volume I Figure 2.1 Projects Planning Process.png (file) | 364 KB | 1 | ||
16:34, 11 March 2020 | DCOM Volume II 2020-03-11.png (file) | 385 KB | DCOM Volume II Cover Page | 1 | |
17:52, 11 March 2020 | MAR-SK-146.pdf (file) | 388 KB | Spring weir | 1 | |
16:28, 11 March 2020 | DCOM Volume III 2020-03-11.png (file) | 408 KB | DCOM Volume III Cover Page | 1 | |
16:29, 11 March 2020 | DCOM Volume IV 2020-03-11.png (file) | 415 KB | DCOM Volume IV Cover Page | 1 | |
19:51, 6 March 2020 | Volume I 2020-03-06.png (file) | 441 KB | 1 | ||
17:55, 11 March 2020 | S-MO-880.pdf (file) | 470 KB | Short Goat and sheep trough | 1 | |
13:30, 30 March 2020 | Borehole Pump House.pdf (file) | 482 KB | Type borehole pump house (with Lister 6 H.P engine & Climax 28/3 well head) | 1 | |
19:52, 6 March 2020 | Volume IV 2020-03-06.png (file) | 488 KB | Volume IV | 1 | |
19:51, 6 March 2020 | Volume II 2020-03-06.png (file) | 505 KB | Volume II | 1 | |
19:52, 6 March 2020 | Volume III 2020-03-06.png (file) | 513 KB | Volume III | 1 | |
13:20, 30 March 2020 | Break Pressure Tank.pdf (file) | 525 KB | Break pressure tank combined with Domestic point and washing slab | 1 | |
14:33, 30 March 2020 | Sand Filter.pdf (file) | 530 KB | Slow sand filter capacity 22.5m3 per day | 1 | |
18:09, 11 March 2020 | TY-TA-5.pdf (file) | 545 KB | Short cattle trough | 1 | |
11:39, 30 March 2020 | TY-ST-40-AutoCAD.dwg (file) | 682 KB | Intake of clear stream-to be found on rock/soft ground | 1 | |
11:17, 30 March 2020 | 22109.dwg (file) | 1.05 MB | Typical sand trap intake | 1 | |
12:21, 30 March 2020 | 90m3 Tank on 6m Riser.dwg (file) | 1.13 MB | 90m3 R.C CIRCULAR TANK ON 6m HIGH CONCRETE BLOCKWORK RISER | 1 | |
12:26, 30 March 2020 | 135m3 Ground Tank.dwg (file) | 1.15 MB | 135m3 CIRCULAR TANK WITH REINFORCED COVER | 1 | |
13:11, 30 March 2020 | 45m3 Tank on 6m Riser.dwg (file) | 1.16 MB | 45m3 R.C CIRCULAR TANK ON 6m HIGH CONCRETE BLOCKWORK RISER | 1 | |
13:09, 30 March 2020 | 45m3 Ground Tank.dwg (file) | 1.19 MB | 45m 3 CIRCULAR TANK WITH REINFORECED COVER | 1 | |
12:34, 30 March 2020 | 135m3 Tank on 6m Riser.dwg (file) | 1.25 MB | 135m 3 R.C CIRCULAR TANK ON 6m HIGH CONCRETE BLOCKWORK RISER | 1 | |
14:39, 30 March 2020 | Domestic Point.dwg (file) | 1.29 MB | Domestic point type 1A & 1B | 1 | |
11:13, 5 January 2020 | Nkrumah.JPG (file) | 1.3 MB | 1 | ||
12:08, 30 March 2020 | 90m3 Ground Tank.dwg (file) | 1.31 MB | 90m3 R.C CIRCULAR TANK GROUND TANK | 1 | |
12:44, 30 March 2020 | 225m3 Ground Tank..dwg (file) | 1.47 MB | 225m3 R.C CIRCULAR TANK ON GROUND | 1 | |
13:06, 30 March 2020 | 225m3 Tank on 6m Riser.dwg (file) | 1.48 MB | 225m3 R.C CIRCULAR TANK ON 6m HIGH CONCRETE BLOCKWORK RISER | 1 | |
13:11, 30 March 2020 | 45m3 Ground Tank.pdf (file) | 1.94 MB | 45m 3 CIRCULAR TANK WITH REINFORCED COVER | 1 |